A smart radiator valve keeps a room at exactly the temperature you want. But it cannot switch the boiler on by itself. Real zone heating control only happens when the valves in each room, a relay at the boiler and an automation work together as one system: if at least one valve is heating, the boiler runs; when all rooms are happy, the boiler stops. It sounds simple, but not every app or hub can read from the valves whether they are actually heating. In this article we show which SONOFF valves work in which system according to the manufacturer and the documentation, what else you need to buy and where it does not work yet.
In short: what you need to know
- A valve controls only its own radiatorThe boiler is switched by a relay or thermostat. Valves control it only through an automation.
- eWeLink: TRV-ZBT Gen2 onlySONOFF describes a setup with the Thermostat Core panel and a gateway (for example NSPanel Pro). The older TRVZB(R) is not supported for this feature.
- Home Assistant + Zigbee2MQTT: both generationsBoth valves report "heating / idle" (running_state). The boiler can be switched by a Shelly 1 Gen3 with a volt-free contact.
- We don't recommend Homey or ZHA yetHomey apps don't offer the valves' heating state. ZHA support for TRV-ZBT Gen2 is not finished yet.
SONOFF TRV-ZBT Gen2Radiator valve. Works in eWeLink and Home Assistant.€29.50
SONOFF Thermostat CoreThermostat with a volt-free boiler contact. Needs a gateway.€34.99
NSPanel Pro 120PWall panel with a gateway for eWeLink.from €109.00
SONOFF Dongle Plus MG24USB adapter for Home Assistant.€29.90How zone control with valves and a boiler works
With a single room thermostat, one room decides for the whole house. When the living room is warm, the boiler stops even if the children's room is cold. Zone control turns this around: every room (zone) has its own valve, schedule and target temperature, and the boiler runs as long as any room still needs heat.
You need three parts:
- A smart valve in every room that measures temperature, opens and closes the radiator valve and reports whether it is heating.
- A controller (a gateway with the eWeLink app, or Home Assistant) that collects the state of all valves and runs the automation.
- A relay with a volt-free (dry) contact at the boiler, wired to the room-thermostat terminals. Contact closed, the boiler heats; contact open, it stops.
The automation boils down to one rule: if at least one valve is heating, switch the boiler on; if none is, switch it off. The key is that the controller can read exactly this state from the valve. Room and target temperature are not enough, because the valve runs its own control loop and may be partly open even just below the target. This is where systems differ.
Which valve in which system: verified table
We checked the details in SONOFF's documentation (guides from November 2026), on the Zigbee2MQTT device pages and in the ZHA repository for Home Assistant. Our shop sells two generations of SONOFF valves: TRVZBR (1st generation, model TRVZB) and TRV-ZBT Gen2.
| System | TRVZB(R), Gen1 | TRV-ZBT Gen2 | What it can read from the valve |
|---|---|---|---|
| eWeLink + SONOFF gateway (NSPanel Pro) + Thermostat Core | no, SONOFF states "TRVZB is not supported" | yes, valve firmware 1.1.0 or later | valve heating state in scenes, sync of up to 5 valves with the panel |
| Home Assistant + Zigbee2MQTT | yes | yes | running_state (idle / heat), temperature, target, valve opening on Gen1 (firmware 1.1.4+) |
| Home Assistant + ZHA | yes, via a quirk | not finished yet (November 2026) | heating state on Gen1, uncertain on Gen2 |
| Homey | partly | not listed | temperature and target, no heating-state flow card in the apps |
The conclusion is clear: for zone control in the eWeLink app you need TRV-ZBT Gen2 valves. If you already own older TRVZBR valves or want maximum flexibility, go for Home Assistant with Zigbee2MQTT.
Option 1: eWeLink, NSPanel Pro and Thermostat Core
This is the route described by SONOFF itself. Everything runs in the eWeLink app with no programming.
What you need
- TRV-ZBT Gen2 valves with firmware 1.1.0 or later, one for every radiator you want to control.
- A SONOFF Zigbee gateway that both the valves and the panel are paired to. From our stock this is the NSPanel Pro 120P or NSPanel Pro Gen2 with firmware 4.9.0 or later. SONOFF also lists ZBBridge-P (3.5.0+), ZBBridge-U (2.6.0+), Bridge-M (1.2.0+) and iHost (2.15.0+). These are currently out of stock and we no longer recommend the older Zigbee Bridge Pro.
- SONOFF Thermostat Core (TP-WGZBA) at the boiler or on the wall. Its volt-free COM/NO output goes to the boiler's room-thermostat terminals. The wiring is explained in detail in SONOFF Thermostat Core: wiring and guide.
- The eWeLink app, version 5.27.0 or later.
Two modes that are easy to mix up
Panel control (sync). One Thermostat Core can be linked with up to 5 TRV-ZBT valves on the same gateway. The panel then sends them its target temperature, mode and schedule. It's convenient, but all linked radiators want the same temperature. SONOFF itself points out that sync does not give you independent room-by-room control. It suits one large zone, for example an open-plan living room and kitchen with three radiators.
Zone control with scenes. Each valve keeps its own temperature and schedule, and two eWeLink scenes decide about the boiler. SONOFF describes them like this:
- Boiler on: when any valve is heating, set the Thermostat Core to a high temperature (for example 30 °C). The contact closes and the boiler heats.
- Boiler off: when all valves enter temperature-maintenance mode, switch the Thermostat Core to frost protection. The contact opens and the boiler stops.
Here the Thermostat Core acts as a "volt-free relay" driven by the scenes. Valves that should keep their own temperature must therefore not be linked to the panel via sync. Sync would send them the panel's temperature, including the 30 °C set by the scene.
Tip: The Thermostat Core output is a volt-free contact rated at max. 3 A. Most boilers have a low voltage on the room-thermostat terminals. Your boiler manual tells you the voltage on that input. If it's 230 V, check in the Thermostat Core manual that the contact can handle it.
As an alternative to the panel, SONOFF also mentions the MINI-D or MINI-ZBD dry-contact relays, switched by the scenes in the same way. The SONOFF Mini D is currently out of stock, so our bundles use the Thermostat Core.
What else TRV-ZBT Gen2 can do in eWeLink
- External thermometer: the valve can control by a SONOFF SNZB-02 sensor (for example SNZB-02M or SNZB-02LD) on the same gateway. The feature is called "Temp. Display from External Sensor". iHost does not support it.
- Open window: on a drop of more than 1.5 °C in 5 minutes, and on Gen2 also via a SONOFF SNZB-04 window sensor on the same gateway. The older TRVZB only detects a temperature drop.
- Presence: with SONOFF presence sensors you can heat only occupied rooms and switch the others to frost protection.
Option 2: Home Assistant, Zigbee2MQTT and Shelly 1 Gen3
For DIY enthusiasts and anyone with older TRVZBR valves. Zigbee2MQTT exposes running_state on both generations with two values: idle and heat. In Home Assistant it appears as the thermostat's heating state (hvac_action), which is exactly what the automation needs.
What you need
- Home Assistant (your own mini PC, Raspberry Pi or Home Assistant Green) with the Zigbee2MQTT add-on.
- A Zigbee adapter: SONOFF Dongle Plus MG24 for USB, or SONOFF Dongle Max with a network (PoE) connection that you can place in the middle of the house.
- Valves: TRVZBR or TRV-ZBT Gen2. You can mix generations.
- A volt-free relay at the boiler: Shelly 1 Gen3 connects over Wi-Fi and is added to Home Assistant locally via the Shelly integration. Don't use an ordinary relay that switches 230 V live on the boiler terminals.
The "at least one valve is heating" automation
A sample automation in YAML. Rename the entities to match your rooms. It runs on every valve state change and, to be safe, every 5 minutes. Besides running_state, it also checks whether a room is at least 0.5 °C below its target, as a safeguard in case a valve reports its state late.
alias: Boiler by valves
mode: restart
triggers:
- trigger: state
entity_id: [climate.living_room, climate.bedroom, climate.kids_room]
- trigger: time_pattern
minutes: "/5"
actions:
- variables:
valves: [climate.living_room, climate.bedroom, climate.kids_room]
heating: >
{% set ns = namespace(n=0) %}
{% for v in valves %}
{% if state_attr(v,'hvac_action') == 'heating'
or (state_attr(v,'current_temperature') | float(99))
< (state_attr(v,'temperature') | float(0)) - 0.5 %}
{% set ns.n = ns.n + 1 %}
{% endif %}
{% endfor %}
{{ ns.n > 0 }}
- if: "{{ heating }}"
then:
- action: switch.turn_on
target: {entity_id: switch.boiler}
else:
- delay: "00:03:00"
- action: switch.turn_off
target: {entity_id: switch.boiler}
The three-minute delay before switching off prevents the boiler from cycling when one valve is closing while another is opening. Valves can also control by an external thermometer. Zigbee2MQTT offers temperature_sensor_select and external_temperature_input for this, but you have to pass the thermometer reading to the valve with an automation in Home Assistant.
Tip: If you don't have Home Assistant and just want to try it in the Shelly app, you can control the boiler with a Shelly 1 Gen3 and a thermometer in one room, without any valves. See the virtual thermostat chapter in Smart thermostat for a gas boiler. For zone control with several valves, however, the Shelly app is not enough.
SONOFF TRVZBR1st generation valve. Zone control via Home Assistant.€22.99
Shelly 1 Gen3Wi-Fi relay with a volt-free contact for the boiler.€13.69
SONOFF Dongle MaxNetwork adapter with PoE and Wi-Fi for Home Assistant.€34.99Where it doesn't work yet
- eWeLink with TRVZBR (1st generation): for panel control SONOFF explicitly states that TRVZB is not supported. Use Home Assistant with Zigbee2MQTT for older valves.
- Home Assistant ZHA with TRV-ZBT Gen2: the change that exposes Gen2 features in ZHA was still only a proposal in November 2026. Until it's part of ZHA, we recommend Zigbee2MQTT.
- Homey: the Homey apps for SONOFF valves offer temperature and target temperature, but no "heating" flow card. An "at least one is heating" automation can't be built reliably.
- Valves without a relay: without a relay or thermostat at the boiler, the valves never switch it on. The boiler then heats according to its own settings.
- Panel sync instead of zones: up to 5 synced valves always share the same temperature. For different temperatures per room you need scenes.
Settings that stop the boiler short-cycling
- Update the valve firmware. TRV-ZBT Gen2 needs firmware 1.1.0, which according to SONOFF also fixed connection drops. TRVZB users reported that with firmware 1.3.0 the valve only started heating about 1 °C below target; firmware 1.4.0 fixed this. Check the valve settings after updating.
- Keep a delay before switching off of 2 to 5 minutes (a delay in Home Assistant, sensible temperatures in eWeLink) so the boiler doesn't start every few minutes.
- Add a temperature safeguard. Zigbee2MQTT users report that TRVZB's running_state sometimes lags behind the actual valve position. Comparing the temperature with the target (as in the sample) handles this.
- Calibrate the valves after fitting and whenever the valve doesn't seem to close fully. See SONOFF TRVZB and TRV-ZBT Gen2: guide.
- Set a sensible flow temperature on the boiler. With zone control the boiler runs for shorter periods, but still according to its own flow-temperature setting.
- Plan for failures. Add a notification when a valve stops reporting (flat batteries) or when the relay stays on for too long.
Ready-made bundles with prices
Zone control following SONOFF's guide: gateway, panel with a volt-free boiler contact and three Gen2 valves.
- NSPanel Pro 120P€109.00
- SONOFF Thermostat Core€34.99
- 3× SONOFF TRV-ZBT Gen2€88.50
For a DIYer with Home Assistant: Zigbee adapter, Wi-Fi boiler relay and three valves.
- SONOFF Dongle Plus MG24€29.90
- Shelly 1 Gen3€13.69
- 3× SONOFF TRV-ZBT Gen2€88.50
Four 1st-generation valves that report their heating state in Zigbee2MQTT, plus a boiler relay.
- SONOFF Dongle Plus MG24€29.90
- Shelly 1 Gen3€13.69
- 4× SONOFF TRVZBR€91.96
You only need as many valves as radiators you want to control. Home Assistant (the computer) is not included in the bundles. More valves are in the Radiator valves category and thermostats in Thermostats.
Troubleshooting
- I can't see the valve's heating state in an eWeLink scene. Check that you have TRV-ZBT Gen2 (not TRVZBR), valve firmware 1.1.0+, gateway firmware (NSPanel Pro 4.9.0+) and eWeLink 5.27.0+. The valves and the panel must be on the same gateway.
- All valves suddenly want 30 °C. They are linked to the panel via sync. Remove the link and control the boiler with scenes only.
- The boiler doesn't respond. The wires must be on the relay's COM and NO, not NC. Boiler terminals often have a factory jumper that must be removed. See the boiler manual.
- The boiler runs although all rooms are warm. In Home Assistant, check hvac_action for every valve. If one shows "heating" for longer than it should, calibrate the valve or update its firmware.
- The boiler starts too often. Lengthen the switch-off delay and avoid very different room schedules that alternate every few minutes.
- The valve has no heating state in ZHA (Gen2). ZHA support is not finished. Zigbee2MQTT exposes it.
- A valve keeps dropping off. Add a mains-powered Zigbee device (router) between the gateway and the valve, for example the Thermostat Core, which also works as a Zigbee router.
Frequently asked questions
Do smart radiator valves switch the boiler on by themselves?
No. A valve only controls its own radiator. The boiler is switched by a relay or thermostat with a volt-free contact, controlled by an automation based on the valves' state.
Which SONOFF valves support zone control in eWeLink?
According to SONOFF, only TRV-ZBT Gen2 with firmware 1.1.0 or later, together with the SONOFF Thermostat Core and a SONOFF gateway (for example NSPanel Pro with firmware 4.9.0+). The older TRVZB(R) is not supported for this feature.
Can I build zone control with older TRVZBR valves?
Yes, in Home Assistant with Zigbee2MQTT. The valve reports its heating state there (running_state idle / heat) and the automation switches the boiler relay accordingly.
Which relay should I use for the boiler?
A relay with a volt-free (dry) contact wired to the room-thermostat terminals, for example Shelly 1 Gen3 or the COM/NO output of the SONOFF Thermostat Core. A relay that switches 230 V live is not suitable for a boiler.
How many valves can the Thermostat Core handle?
In sync mode you can link it with up to 5 TRV-ZBT valves, which then share the panel's temperature. For zone control with scenes you don't link the valves to the panel, so each keeps its own temperature.
Does it work with Home Assistant ZHA?
For TRVZB yes, via a quirk. For TRV-ZBT Gen2, ZHA support was not finished in November 2026, so we recommend Zigbee2MQTT.
Does it work with Homey?
Not reliably. The Homey apps for SONOFF valves have no heating-state flow card, so an "at least one valve is heating" automation has nothing to work with.
Do I need a room thermostat with zone control?
No. The valves in the rooms take over the thermostat's role. At the boiler, a volt-free relay controlled by the automation is enough.
Can the valves use a separate thermometer?
Yes. In eWeLink, TRV-ZBT Gen2 supports external SONOFF SNZB-02 sensors on the same gateway (except iHost). In Zigbee2MQTT you pass the thermometer reading to the valve with an automation.
How do I stop the boiler from short-cycling?
Set a switch-off delay (2 to 5 minutes), update the valve firmware and avoid room schedules that alternate every few minutes.
Build your zone heating control
For eWeLink choose TRV-ZBT Gen2, Thermostat Core and NSPanel Pro. For Home Assistant, valves, a Zigbee adapter and a Shelly 1 Gen3 at the boiler are all you need.
View radiator valves